Datalogic Mobile S.r.l. Vitalino 1340012 - Lippo di Calderara di Reno Bologna - ItalyF734-ESeries TerminalsEd.: 01/2008ALL RIGHTS RESERVEDDatalogic Mobile reserves the right to make modifications and improvements without prior notification.Datalogic Mobile shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies.© Datalogic Mobile S.r.l.

CONVENTIONSThis manual uses the following conventions:“User” or “Operator” refers to anyone using a F734-ETerminal. “Device” refers to the F734-ETerminal.“You” refers to the System Administrator or Technical Support person using this manual to install, operate, maintain or troubleshoot a F734-ETerminal.

Datalogic Formula 734-E Parts and accessories. Pour tout renseignement vous pouvez vous adresser datalogc site web: View your entire shopping cart. Operation is subject to the following two conditions: Page 46 Random Access Memory. Formula 734-E - read user manual online or download in PDF format. Datalogic Formula 734-E 941504190 Leaflet. Product codes. Download Like.

REFERENCE DOCUMENTATIONFor further details refer to the Manuals of the various programs provided on the CD-ROM. SERVICES AND SUPPORTDatalogic Mobile provides several services as well as technical support through its website. Read this manual carefully before performing any type of connection or repair on the terminal.The user is responsible for any damages causedby incorrect use of the equipment or byNOTEinobservance of the indication supplied in thismanual.GENERAL SAFETY RULESUse only the components supplied by the manufacturer for the specific F734-Eseries terminal being used. The use of cradles other than those supplied with the terminal or indicated in the list in the appendix could cause serious damage to the terminal.Do not attempt to disassemble the F734-Eseries terminal, as it does not contain parts that can be repaired by the user.

Any tampering will invalidate the warranty.When replacing the batteries or at the end of the operative life of the terminal, disposal must be performed in compliance with the laws in force.Do not submerge the terminal in liquid products.vi. INTRODUCTION1The F734-Eseries terminals have a backlit LCD graphic display of 16 characters by 4 lines plus a line in the upper part of the display for the programmable icons:The icons which canThe batterybe controlled by thecharge statusapplication programTimeF734-ESERIES TERMINALS DATALOGIC S.P.A. 4 LINES 16 CHARSFigure 5 - Terminal Display 1.2 APPLICATION DEVELOPMENT PROGRAMSBy using the optional EasyGen™ Application Generator or the DS for Formula™ software package, developers can easily customize applications according to the end user specific needs, solving the most common data collection applications such as inventory, picking and shipping/receiving.EasyGen™ is the ideal solution for making Formula 734-E batch terminals productive instantly. In a familiar environment, developers have all the instruments at their disposal to reduce programming times (and therefore costs) while maintaining a high standard of quality in the creation of personalized applications whatever their nature, whether simple (e.g. A program for inserting codes/quantities) or more sophisticated.The EasyGen™ package includes Systools™ 2001, the efficient software utility to transfer data to standard ASCII files, and OLE for Formula, the software module ActiveX - OLE Custom Control or OCX - allowing users to easily integrate their data into applications such as Visual Basic, Excel, Access, Delphi, etc (see par.

1.2 or par.1.3 for details).DS for Formula™ is a software package that provides instruments for fully exploiting F734-E and F734-E/RF terminals by creating fully-structuredand personalized applications (see par.1.2 for details).3. F734-ESERIES TERMINALS1DS for Formula™ uses a «C» standard ANSI compiler, integrated with special libraries, operating in an MS-DOSenvironment and developed specifically for the type of terminal processor. The libraries, developed by Datalogic Mobile, permit direct management of the terminal functions. INTRODUCTION1 1.4 PACKAGE CONTENTSThe F734-Eterminal package includes:− n.

1 F734-Eterminal complete with batteries;− n. 1 user's manual− n. 1 test chartThe F734-E/RFterminal package includes:− n. 1 F734-E/RFterminal complete with batteries;− n. 1 user's manual− n.

1 test chartRemove all components from their packing and check that they are in good condition and that they correspond to the shipment documents.Keep the packing and boxes in case it is necessary to send the terminal back forCAUTION technical assistance. Damage caused by improper packing is not covered by the warrantyRechargeable battery packs are not initiallycharged. Therefore the first operation to performis to charge them in the appropriate cradle (seeNOTEpar. 2.2.1 and par.4.1).1.5 ACCESSORIESF951/CChargerF951 – F951 DarkTransceiver/Charger - RS232/RS485F951/VVehicle Transceiver/Charger RS232/RS485 (without power supply)F950/4/CCharger - 4 slotsF950/4Transceiver/Charger - 4 slots - RS232 (x1) / RS485 (x4)F950/4/RS232Transceiver/Charger - 4 slots - RS232 with NCK for RS485F902T-Box5. F734-ESERIES TERMINALS2 2.2.2 Connection with Eavesdrop InterfaceThe cable Kit 94A054030 provides two cables; one for Eavesdrop connections and one for Modem connections.The Eavesdrop connection enables the F734-Eterminal to be connected to an existing asynchronous RS232 line (for example between the host computer and video terminal).The modem connection enables the terminal to be connected to a host system using a modem.A BCDEFigure 9 - Eavesdrop and Modem ConnectionKey:A) Video terminalB) Host computerC) Cradle F951D) Power supplyE) Modem10. CONNECTIONS2 2.2.3 RS485 ConnectionThe RS485 line allows connecting several terminals to a single RS232 line by means of a network (see the 'Formula 904/N User Manual).If the network is made using the Formula 902 T-Box,the line can be extended up to 1200 meters and up to 32 different types of Formula cradles can be connected.

If multiple cradles are used, the individual work stations must be counted.The RS485 connection is the only one allowing all the stations of a multi-cradleto be available for transmission/reception from the host computer.NOTE11. USE AND OPERATION3ARROW KEYS: only available for the application when not in “Select or Data Edit” mode.SCAN KEY: activates the laser for barcode scanning and turns on the terminal when it is off.FUNCTION KEYS: keys, and are available for the loaded application. F734-ESERIES TERMINALS3display’s contrast increases to the allowed maximum, and then returns to 0 value.NUMERIC KEYS: allow the entry and display of the main numeric symbol.

If the has first been pressed, the choice of alternative alphabetic characters will be activated.BACKSPACE KEY: deletes the last character entered.SPACE KEY: allows the introduction of a blank space. If the has been pressed previously, the choice of alternative characters will be activated.ENTER KEY: allows validation of what has been typed.PROTECTED RESET BUTTON: it is activated by inserting a blunt object in the slot while simultaneously pressing the key.18.

USE AND OPERATION3 3.2 BARCODE SCANNINGWhen reading a barcode point the terminal laser beam at the code from an appropriate distance and simultaneously press the key. The beam emitted by the laser must completely cover the barcode; the LED (and the acoustic signal, if activated) will indicate if the scan was carried out correctly.NONOOKOKFigure 16 - F734-ESeries Terminal Scanning a BarcodeThroughout the operation of the application, the battery icon, and the time icon will always be activated, the latter in accordance with the setting of the terminal internal clock.In addition, when an acoustic signal is emitted,NOTEthe loudspeaker icon will appear.19.

F734-ESERIES TERMINALS4 4 MAINTENANCERechargeable battery packs (NiCd/NiMh) are notinitially charged. Therefore the first operation toperform is to charge them in the appropriateNOTEcradle.

See chapter 2 and the following paragraph'Charging the Batteries'.4.1 CHARGING THE BATTERIESBattery charge life depends on many variables but, under normal conditions, autonomy is more than enough for a day work.Information on the battery-chargestatus is provided by the dedicated icon on the display. Fast rapidshare downloader. The information provided by the icon is valid only when the terminal is not inserted in the cradle.Four different charge levels are given from a maximum value (all the icon segments full) to a minimum one which warns of pre-low-battery (icon empty and intermittently flashing).Recharging should be made after using the terminal until the batteries are nearly flat.When the terminal display window shows the message 'BATTERY LOW', wait until it is turned off before inserting it in the cradle.CAUTIONRecharge the terminal by simply inserting it into its cradle; Datalogic Mobile S.r.l.

Recommends a minimum uninterrupted recharging time of eight hours. When using the NiMh battery a standard recharge does not allow taking fully advantage of the improved battery technology. For this reason, a recharging time of about 60 hours is advised to get the NiMh maximum capacity.When batteries are new, or have not been recharged for a long time, it is necessary to perform two or three charge and discharge cycles (with complete use) before the batteries are able to reach their maximum capacity.22. MAINTENANCE4During the battery recharge the color of the LED positioned on the cradle changes from red to green.

If using the NiCd battery pack, the LED color changes when 70-80%of the complete charge is reached. If using the NiMh battery pack,NOTE the LED color changes when 50-60%of the complete charge is reached due to the batteryincreased capacity.If the terminal remains inactive for a prolonged period such as two weeks, it is advisable to download all the stored data ontoa computer and extract the battery pack.CAUTION23. MAINTENANCE43- Replace the battery pack, making sure the batteries are inserted in the right direction as indicated within the case.- +- +Before inserting the battery pack into the terminal, ensure the battery polarity matches with the one indicated within the case.CAUTIONCONTACTSFigure 19Figure 20When inserting the battery pack, first slide it towards the springs compressing them until the contacts at the other end are cleared (see Figure 18). Then, push downwards to insertthe pack (see Figure 19). Be very careful not CAUTION to damage the contacts when pushingdownwards.4- Close the battery cover and tighten the screwsDo not incinerate, disassemble, shortterminals or expose to high temperature.

Riskof fire, explosion. Use specified charger only.Risk of explosion if the battery is replaced byWARNINGan incorrect type. Dispose of the batteries asrequired by the relevant laws in force.25. BarcodeA pattern of variable-widthbars and spaces which represents numeric or alphanumeric data in binary form.

The general format of a barcode symbol consists of a leading margin, start character, data or message character, check character (if any), stop character, and trailing margin. Within this framework, each recognizable symbology uses its own unique format.Baud RateA measure for data transmission speed.BitBinary digit. One bit is the basic unit of binary information. Generally, eight consecutive bits compose one byte of data.

The pattern of 0 and 1 values within the byte determines its meaning.Bits per Second (bps)Number of bits transmitted or received per second.ByteOn an addressable boundary, eight adjacent binary digits (0 and 1) combined in a pattern to represent a specific character or numeric value. Bits are numbered from the right, 0 through 7, with bit 0 the low-orderbit. One byte in memory can be used to store one ASCII character.DecodeTo recognize a barcode symbology (e.g., Codabar, Code 128, Code 3 of 9, UPC/EAN, etc.) and analyze the content of the barcode scanned.EEPROMElectrically Erasable Programmable Read-OnlyMemory. An onboard non-volatilememory chip.

Datalogic Formula 734 Software Manual

Data is maintained when power is not present.FLASHIt is a type of non-volatilememory that can be erased and reprogrammed in units of memory called blocks. It is a variation of EEPROM memory which, unlike flash memory, is erased and rewritten at the byte level, and therefore is slower than flash memory updating. Data is maintained when power is not present.30. HostA computer that serves other terminals in a network, providing services such as network control, database access, special programs, supervisory programs, or programming languages.Liquid Crystal Display (LCD)A display that uses liquid crystal sealed between two glass plates. The crystals are excited by precise electrical charges, causing them to reflect light outside according to their bias. They use little electricity and react relatively quickly. They require external light to reflect their information to the user.Light Emitting Diode (LED)A low power electronic light source commonly used as an indicator light.

Datalogic Usa

It uses less power than an incandescent light bulb but more than a Liquid Crystal Display (LCD).RAMRandom Access Memory. Data in RAM can be accessed in random order, and quickly written and read. This memory is volatile and therefore data is lost when power is not present.RTCReal Time Clock.TerminalA Datalogic portable computer product.31.